Specification
- Cummins® X2.5 series, 3 cylinder, In-line 4 stroke, radiator cooled engine
- Robust and efficient air handling system
- Dry type, replaceable paper element air cleaner with restriction indicator
- Optimized turbocharger for increased altitude capabilities
- Optimized fuel consumption with inline fuel pump and A1 class mechanical governing
- Spin-on fuel filter
- Cooling system designed and tested for 45°C ambient conditions
- Full flow spin-on lube oil filter
- First fill of lube oil and coolant
- Electrical starter motor with soft start engagement feature
- Battery charging alternator
- 1 x 12V DC battery
- STAMFORD S0L1 and S0L2 alternator frames from Cummins Generator Technologies
- Brushless type, Screen protected, Revolving field
- Self-excited alternator conforming to IS/IEC 60034-1
- Better motor starting capability
- Best in class efficiency
- Compact design with sealed bearings for longer life and lesser maintenance
- Impregnation on all wound components for better mechanical strength
Control panel is powder coated for weather-proof and longlasting finish. The control panel consists of the following parts:
- PS0600 Controller
- Bus bars with suitable capacity with incoming/outgoing terminals
- Indicating lamps for ‘Load ON’ and ‘Set Running’
- Instrument fuses duly wired and ferruled
- MCCB of suitable rating with short circuit protections
- AC/DC separation inside control panel for safety
- Specially designed to meet stringent MoEF/CPCB norms of 75 dBA @ 1 mtr at 75% load under free field conditions
- The acoustic enclosure is made of CRCA sheets in Munsell green shade and a structural/sheet metal base frame painted in black
- 11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment
- High quality noise absorbent and fire-retardant grade acoustic insulation material (P.U Foam) complying to IS 8183
- Top lifting for easy handling at customer site
- Designed to have optimum serviceability
- Air inlet louvers specially designed to operate at rated load
- Fluid drains for lube oil and fuel
- External fuel filling arrangement outside the enclosure
- Cummins® PowerStart™ PS0600 control is a microprocessor based generator set monitoring, metering and control system with LCD display
- AMF functionality
- Intuitive operator interface with LED backlit 128×64 pixel graphic display, tactile soft switches and generator set status LED lamps
- Remote start-stop
- Audible and visual warning for inducement
- Engine metering: Oil pressure, engine temperature, starting battery voltage, engine running hours
- AC alternator metering: L-L voltage and L-N voltage, current (phase and total), kVA (phase and total), frequency, kWh, kW, PF, utility voltage and frequency
- Engine protection: Low lube oil pressure, high/low coolant temperature, battery high/low/weak volts, fail to crank/start, sensor failure, cranking lockout, low fuel level
- AC alternator protection: Over/under voltage, over/under frequency, loss of AC sensing, overspeed, over current, kW overload
- Data logging: Engine hours, control hours and up to 5 recent fault codes
- Configurable glow plug control
- 12 Volt DC operation
- Sleep mode
- Modbus interface (RS485 RTU)
- InPower compatible (PC based service tool)
- Certifications: Meets requirements of ISO, EN, Mil Std. and CE standards
- Maintenance due alarm based on engine run time and due date
- Exerciser scheduler
Generator Set Specification
| KVA | 7.5 | 10 | 15 | 20 | 25 | 30 |
|---|---|---|---|---|---|---|
| Specification | CI 7.5D5P | CI 10D5P | CI 15D5P | CI 20D5P | CI 25D5P | CI 30D5P |
| Duty | Prime | Prime | Prime | Prime | Prime | Prime |
| Power Rating (kVA/kWe) | 7.5/6 | 10/8 | 15/12 | 20/16 | 25/20 | 30/24 |
| No. of Phases | 3 Phase | 3 Phase | 3 Phase | 3 Phase | 3 Phase | 3 Phase |
| Voltage & Frequency | 415V, 50 Hz | |||||
| Power Factor | 0.8 (lagging) | |||||
| Current (A) | 10 | 14 | 21 | 28 | 35 | 42 |
| RPM | 1500 | |||||
Engine Specification
| KVA | 7.5 | 10 | 15 | 20 | 25 | 30 |
|---|---|---|---|---|---|---|
| Specification | CI 7.5D5P | CI 10D5P | CI 15D5P | CI 20D5P | CI 25D5P | CI 30D5P |
| Make | Cummins® | |||||
| Model | x2.5-G5 | x2.5-G5 | x2.5-G6 | x2.5-G6 | x2.6-G1 | x2.6-G1 |
| Required Certified Power for Rated kVA (hp) | 16.8 | 16.8 | 25.2 | 25.2 | 41.2 | 41.2 |
| Cooling | Liquid Cooled (EG Compleat 50:50) | |||||
| Aspiration | Turbocharged | |||||
| No. of cylinders | 3, In-line | |||||
| Bore (mm) x Stroke (mm) | 91.4 X 127 | |||||
| Compression ratio | 18.5:1 | |||||
| Displacement (litre) | 2.5 | |||||
| Fuel | High Speed Diesel | |||||
| Performance class of generator set | ISO 8528-5 G2 | |||||
| Starting system | 24 V DC Electrical | |||||
| Lube oil specification | CI4+ | |||||
| Lube oil sump capacity, High-Low level (litre) | 4-3 | |||||
| Total lubrication system capacity (Litre) | 8-5 | |||||
| Total coolant capacity (litre) | 5.5 | |||||
| Exhaust pipe size (inch) | 2 | |||||
| Total wet weight (Engine+Radiator)* (kg) | 271 | 271 | 271 | 271 | 320 | 320 |
| Length X Width X Height (Coolpac) (mm) | 718 x 651 x 883 | |||||
| Mean Piston speed (m/s) | 6.3 | |||||
| Combustion air intake @100% load (±5%) (cfm) | 41.4 | 41.4 | 50.2 | 50.2 | 66 | 66 |
| Exhaust Temperature (°C) | 380 | 380 | 500 | 500 | 410 | 410 |
Alternator Specification
| KVA | 7.5 | 10 | 15 | 20 | 25 | 30 |
|---|---|---|---|---|---|---|
| Specification | CI 7.5D5P | CI 10D5P | CI 15D5P | CI 20D5P | CI 25D5P | CI 30D5P |
| Make | STAMFORD (CGT) | |||||
| Alternator Frame | S0L1-D | S0L1-H | S0L1-P | S0L2-M | S0L2-M | S0L2-P |
| Enclosure | IP23 | |||||
| Voltage regulation (Max.) | ±0.5% | |||||
| Class of Insulation | H Class | |||||
| Winding Pitch | 2/3 | |||||
| Stator Winding | Double layer concentric | |||||
| Rotor | Dynamically Balanced | |||||
| Waveform distortion / THD | No load < 1.5%, Non distorting balanced linear load < 5% | |||||
| Maximum Unbalanced Load | ≤ 25% | |||||
| Telephonic Harmonic factor | < 2% | |||||
Typical Enclosed Genset Dimension
| Rating (kVA) | Genset Model | Length (mm) | Width (mm) | Height (mm) | Wet Weight* (kg) | Standard Fuel Tank Capacity (litre) |
|---|---|---|---|---|---|---|
| 7.5 | CI 7.5D5P | 2090 | 875 | 1150 | 772 | 85 |
| 10 | CI 10D5P | 2090 | 875 | 1150 | 780 | 85 |
| 15 | CI 15D5P | 2190 | 875 | 1150 | 789 | 90 |
| 20 | CI 20D5P | 2190 | 875 | 1150 | 820 | 90 |
| 25 | CI 25D5P | 2400 | 950 | 1400 | 1029 | 102 |
| 30 | CI 30D5P | 2400 | 950 | 1400 | 1029 | 102 |
Frequently Asked Questions – KY Enterprise Diesel Generator
1. What power capacities are available in your Diesel Generator range?
KY Enterprise offers a wide range of Diesel Generator, Diesel Generator Set, and Power Backup Generator solutions in various capacities for residential, commercial, and industrial applications.
2. Are your Diesel Generators fuel-efficient?
Yes, our Silent Diesel Generator and Industrial Diesel Generator models are designed with advanced engine technology to provide excellent fuel efficiency, lower operating costs, and reliable performance.
3. Can the DG Set run continuously during power cuts?
Yes, our DG Set Manufacturer solutions are suitable for both prime and standby applications, ensuring continuous and stable power during extended outages.
4. Do your generators comply with CPCB emission and noise standards?
Yes, every Silent DG Set supplied by KY Enterprise complies with CPCB IV+ emission norms and features an acoustic enclosure for low-noise operation.
5. What type of fuel does the Diesel Generator Set use?
Our Diesel Generator Set operates on High-Speed Diesel (HSD), delivering dependable performance with easy fuel availability.
6. Are your generators suitable for commercial and industrial use?
Yes, our Industrial Diesel Generator range is ideal for offices, factories, hospitals, hotels, schools, warehouses, construction sites, and other commercial facilities.
7. What Generator Maintenance is required?
Proper Generator Maintenance includes checking engine oil, coolant levels, air filters, battery condition, fuel filters, and scheduling regular servicing to maximize the life of your Diesel Genset.
8. What is the recommended service interval for a Diesel Genset?
Most Diesel Genset models require servicing every 500 operating hours or as recommended by the manufacturer to ensure reliable performance.
9. Does KY Enterprise provide warranty on Diesel Generator Sets?
Yes, KY Enterprise supplies genuine Diesel Generator Set products backed by the applicable manufacturer warranty. Warranty coverage depends on the model and brand.
10. Why choose KY Enterprise as your Diesel Generator Supplier?
KY Enterprise is a trusted Diesel Generator Supplier and Diesel Generator Manufacturer partner, offering genuine Generator, Silent Diesel Generator, Power Backup Generator, installation support, competitive pricing, and dependable after-sales service.